Air Movers (pneumatic):
The low-wear and mobile pneumatic air movers are functioning according to the Venturi pricnciple. The venting or suction of damp and gas is possible in the ATEX area of zone I and II as well. There are nominal diameters of 100 mm up to 219 mm available. The operating pressure is 2-6 bar.
ORDER NO. | ATEX Specification | Operating pressure | Nominal diameter | Volume flow (unrestricted sucking) at 6 bar | Air consumption (at 2-6 bar) | Noise level LpA | Vibration level | Weight |
---|---|---|---|---|---|---|---|---|
bar | mm | m³/min | m³/min | dB(A) | m/s² | kg | ||
8 1614 0010 | II2GExhIIBT6Gb | 2-6 | 100.00 | 14.5 | 1.6-2.3 | 100.8 | 3.28 | |
8 1616 0010 | II2GExhIIBT6Gb | 2-6 | 125.00 | 20.8 | 1.7-2.4 | 101.1 | 3.86 | |
8 1618 0010 | II2GExhIIBT6Gb | 2-6 | 150.00 | 40.0 | 2.8-4.37 | 103.8 | 5.16 | |
8 1620 0010 | II2GExhIIBT6Gb | 2-6 | 180.00 | 47.2 | 2.9-4.5 | 104.4 | 5.34 | |
8 1622 0010 | II2GExhIIBT6Gb | 2-6 | 200.00 | 65.3 | 6.3-9.7 | 115.8 | 6.84 | |
8 1624 0010 | II2GExhIIBT6Gb | 2-6 | 250.00 | 85.1 | 6.4-9.5 | 116.3 | 7.96 | |
8 1634 0010 | IM2ExhIMbT6 | 2-6 | 101.60 | 15.0 | 1.6-2.3 | 100.8 | 4.80 | |
8 1634 001C | II2GExhIICT6Gb | 2-6 | 101.60 | 15.0 | 1.6-2.3 | 100.8 | 4.80 | |
8 1636 0010 | IM2ExhIMbT6 | 2-6 | 129.00 | 22.1 | 1.7-2.4 | 101.1 | 5.60 | |
8 1636 001C | II2GExhIICT6Gb | 2-6 | 129.00 | 22.1 | 1.7-2.4 | 101.1 | 5.60 | |
8 1638 0010 | IM2ExhIMbT6 | 2-6 | 154.00 | 42.2 | 2.8-4.37 | 103.8 | 7.50 | |
8 1638 001C | II2GExhIICT6Gb | 2-6 | 154.00 | 42.2 | 2.8-4.37 | 103.8 | 7.50 | |
8 1640 0010 | IM2ExhIMbT6 | 2-6 | 168.3 | 41.3 | 2.9-4.5 | 104.4 | 7.70 | |
8 1640 001C | II2GExhIICT6Gb | 2-6 | 168.30 | 41.3 | 2.9-4.50 | 104.4 | 7.70 | |
8 1642 0010 | IM2ExhIMbT6 | 2-6 | 204.00 | 67.9 | 6.3-9.7 | 115.8 | 9.90 | |
8 1642 001C | II2GExhIICT6Gb | 2-6 | 204.00 | 67.9 | 6.3-9.70 | 115.8 | 9.90 | |
8 1644 0010 | IM2ExhIMbT6 | 2-6 | 219.10 | 75.2 | 6.4-9.5 | 116.3 | 11.50 | |
8 1644 001C | II2GExhIICT6Gb | 2-6 | 219.10 | 75.2 | 6.4-9.50 | 116.3 | 11.50 |